For further information please contact SLE Cladding Ltd. Tel. 01948 666 321. Fax.  01948 66 55 32.
 
DEEPLAS CLADDING.
Detailed Fixing instructions for Deceuninck's
Specification of Battens.
Use Deeplas 20 x 30mm PVC-u battens (ref. 9050) or timber - minimum 27 x 40mm.
Use good quality, preservative treated timber.
Fix battens to sound substrate at 600mm centres or closer.
Where a CCA (chrome/copper/arsenic) preservative is used, allow approximately 7 days before fitting cladding.
 
Specification of Fixings.
Material Stainless Steel. Type Annular ring-shaft nails. (use plastic heads where visible). Diameter 2mm.  Length for planks, minimum of 30mm (ref.1096). For Trims, minimum of 20mm. Use galvanised clout nails for timber battens. 
 
Cladding Fixing
 

Summary

Colour White
Product Cladding
Thickness 6 mm
Fixing Polytop stainless nails 30mm long, notched (1096)
No. fixings per location 2
Max. fixing centres (mm) 600mm (400mm exposed locations)
Support Plank or batten
Support gap 600mm (400mm exposed locations
Expansion
Always allow 10 mm expansion gap between ends of planks. Fix from centres and work outwards.
Thermal movement.
Allow a minimum of 5mm clearance at the end of each 5 metre length of profile, in order to accommodate expansion. (Foiled 8mm expansion).
Windloadings
Maximum windloading based on 600mm battens spacing.
100mm cladding... 2000Pa
150mm cladding... 1350Pa
For increased wind loadings reduce batten spacings and fixing centres and check with qualified engineer. As a guide 400mm batten spacings should be considered for applications over 2 storeys high.
Fixing to non weatherproof substrates.
For applications involving non weatherproof substrates (e.g. timber stud wall) a vapour permeable water barrier must be installed behind the battens and cladding. When used as a decorative facing on weathertight masonry wall, a watertight barrier is not generally necessary. The same applies for fixing distances.
Caution
Cladding should not be taken into account when designing a timber stud to resist racking forces. Do not install cladding at ground floor level where severe impact will occur. Coloured cladding is not covered under the 10 year guarantee.
Installation.
Vertical Cladding Fix battens horizontally Horizontal Cladding Fix battens vertically Diagonal Cladding Fix battens horizontally
Fixing battens.
Start by fixing battens to the building framework on top of the permeable membrane. Battens will also need to be fixed around the periphery of any openings e.g. a window.

Vertical Trim

Fixing starter trims.
Before fixing the initial starter trim, make a final inspection of the building substrate and check if any special consideration needs to be taken into account with regard to drainage and ventilation.
Work from a line level, fix the starter trim to the lower timber batten. Use 20mm trim nails.
All vertical trims should be fixed to perimeter battens.

Starter Trim

Fixing cladding top finish trim.
Top trims and trims around windows should be fixed to perimeter battens. Note. top trim with head drip is also available. (Ref. 1928).

Top Finish

Fixing internal/external corner trim.
Note. The same product works as both an internal and external corner trim. Fix the back half initially and clip the cover on after cladding has been fitted.

Internal Corner External Corner
Temperature of use
Profiles should not be fixed when temperature is below 0 deg. C or above 30 deg. C. Before using profiles, acclimatise them to the temperature of the workplace. (i.e. do not use warm profiles straight away on a cold site).
Tools.
The system components are easy to work using normal woodworking tools for cutting, drilling and shaping.
Handsaws, use a fine toothed blade. Powertools, use a Carbide tipped blade with running speeds similar to or preferably higher than those used for timber.
Maintenance
Cleaning
Profiles can be washed with water and mild, non-abrasive detergent. Solvent based cleaners or cleaning agents containing chlorine should not be used. Contact with composites based on bitumen should also be avoided. You can also use our cleaning agent "Decoclean" specially developed to clean PVC-u products.
Painting
Painting of the product is not recommended. It can cause embrittlement and dark colours will cause thermal distortion.
Repairs
Scratches are difficult to repair entirely, but they can be polished out using wet and dry papers. Start with an appropriate grade (180 or 360) moving down to 1000 grade. Finally polish with a cream cleaner.
Sealant.
Use a low modulus silicone sealant conforming to BS5809. Refer to chosen manufacturers recommendation. Note. Primers may be necessary when bonding to certain materials.
   
 
For further information please contact SLE Cladding Ltd. Tel. 01948 666 321. Fax.  01948 66 55 32.