TRISOMET333 FIXING NOTE. This page of drawings has been retained from the Corus's former 32/1000 profile and catalogue. Whilst the same lapping and other details apply to the new 333 profile, (we think these drawings explain the basic layout better). For Trisomet333 fixing positions please refer to the drawing at bottom of the Span/loading table page. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ROOFLIGHT - end lap detail | ROOFLIGHT - end lap detail | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Primary fastener, 5.5mm dia. self drilling austenitic SS. high thread fastener with sealing washer | Rooflight ends must be supported by at least 50mm | Extension plate 1.6mm galvanised standard 3m length | Primary fastener, 5.5mm dia. self drilling austenitic SS. high thread fastener with sealing washer | Rooflight ends must be supported by at least 50mm | Extension plate 1.6mm galvanised standard 3m length | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
![]() |
||||||||
| 10 x 5mm PE foam tape (3 runs) Do not layer over the top of the end crown (as shown above) | Galvanised Z Purlin | 50 x 5mm PE foam tape, continuously laid to ensure air tightness | 10 x 5mm PE foam tape (3 runs) Do not layer over the top of the end crown (as shown above) | Galvanised Z Purlin | 50 x 5mm PE foam tape, continuously laid to ensure air tightness | ||||
| Roof End Lap | Roof Ridge | ||||||||
| Primary fastener, 5.5mm dia. self drilling austenitic SS. high thread fastener with sealing washer |
Galvanised Z Purlin
|
Ridge flashing, butt or lap jointed, sealed with 2 runs of continuous high performance strip sealant | Profiled Filler sealed top and bottom | Flashing stitched with sealed or self drilling fasteners with sealing washers no greater than 400mm centres | |||||
![]() |
![]() |
||||||||
| 10 x 5mm PE foam tape (3 runs) Do not layer over the top of the end crown (as shown above) | 50 x 5mm PE foam tape, continuously laid to ensure air tightness | Primary fastener, 5.5mm dia. self drilling austenitic SS. high thread fastener with 19mm sealing washer | Injected Foam or possibly Rockwool Insulation quilt. | Internal flashing butt or lap jointed sealed with two runs of continuous high performance strip sealant 9 x 3mm | 10 x 5mm PE foam tape (3 runs) Do not layer over the top of the end crown (as shown above) | ||||