ROCKWOOL (FIREWALL) COMPOSITE CLADDING

FIXING DETAILS

LPCB Approved Drawing.  Firewall & Firewall Plus Joint Detail

 

LPCB Approved Drawing.  A typical Wall/Floor Junction - 1 As an alternative to the heavy steel angle SLE Cladding can fold a channel to size in 0.7mm Plastisol or White Polyester

 

LPCB Approved Drawing.  A typical Wall/Floor Junction - 2 As an alternative to the heavy steel angle SLE Cladding can fold a channel to size in 0.7mm Plastisol or White Polyester. For fitting the top close under an existing ceiling, Light Angle in White Polyester is a neat easy fixing method.

LPCB Approved Drawing.  A typical Wall/Floor Junction - 2

 

3mm Horizontal Joint. A cross section showing the concealed TEK Screw.

135mm Core (k 0.0427) U value = 0.35 W/m2 degrees C

    

 
     