For further information please contact SLE Cladding Ltd. Tel.
01948 666 321. Fax. 01948 66 55 32
|
|
ONDUTILE |
|
New 24mm Isoline base sheet |
|
|
|
Picture shows standard Onduline 38mm sheet previously used as a Ondutile sheet above the new 24mm Isoline Ondutile development. |
| ONDUTILE DEVELOPMENT |
| Since its introduction on to the UK market in 1989, the Ondutile system has been continually developed to become the acknowledged market leading independent secondary weatherproof roof underlay system for low pitch tile, slate and applications and shingle applications. |
| Reduced roof pitches for tiles slates and shingles |
| Immediate weather protection |
| Easy to handle and fix on site |
| Improved ventilation, moisture control and thermal performance |
| Security of durable secondary roof |
| New Ondutile Lowline base sheet |
| With the introduction of
a new Onduline low-line base sheet the Onduline system now offers the
choice of two base sheets to select from.
Existing Onduline
PPHR high ventilation. |
|
|
|
A typical snow cover tile roof with 24mm Isoline base sheet |
|
FIXING SPECIFICATION The detailed design and fixing instructions are described in the Onduline leaflet. The main difference in the fixing instructions bring the size and type of the fixing required to nail through the tile batten through the top of the low-line sheet corrugation and into the Onduline support batten or decking. Please refer to the main Ondutile leaflet mechanical fixing section (CLICK HERE) and amend as follows :- Mechanical fixing specifications Ondutile low-line base sheets are laid with a double corrugation side lap and 200mm end lap. A sheet under normal conditions will provide 1.7m2 coverage compared to the 1.5m2 of a standard Onduline PPHR sheet. |
|
|
|
Onduline 24mm Lowline profile. Reduction in roof section 24mm |
| 24mm Isoline base sheet |
| So now the choice is yours. Select either the existing proven Ondutile; or the new Ondutile Low-line profile base sheet to suit your roof design requirements. Allowing roofing tiles and slates to be laid below the manufacturers minimum recommended roof pitch with confidence. Lower your roof pitch not your expectations |
| Sheet end lap | 200mm |
| Sheet coverwidth | 1.800m |
| Sheet side lap | 2 corr. 96mm |
| Sheet cover | 1.800 x 0.960m |
| Average sheet coverage | 1.700m2 |
|
Type |
Colour |
Dimensions |
Weight |
Corrugation width |
Corrugation Height |
Ventilation per sheet |
Profile |
|
Onduline PPHR |
Black |
2m x 0.950m |
6.4kg |
95mm |
38mm |
17,000mm per lin. metre |
|
|
|
|||||||
|
Onduline Lowline |
Black |
2 x 1056m |
6.5kg |
48mm |
24mm |
10,500mm per lin. metre |
|
| ROOF VENTILATION |
| Ondutile forms a cold roof
section and requires ventilation above and below the Onduline sheet,
if decking is used, slots in the decking can be provided at high and
low levels to form ventilation channels utilising the sheet
corrugations which contribute 10,500mm2 per linear metre ventilation
to the total ventilation requirement This is sufficient low level
ventilation at the eaves Roof pitches of 15%v or more requiring 10,000mm2 per linear metre high level. The ventilation requirement is set out in the Ondutile leaflet |

Above drawing showing high level of ventilation below tiles
NOTE. Being a new product. At the time of writing the "Ondutile Lowline" base sheet is not covered within the existing BBA certification.
For further information please contact SLE Cladding Ltd. Tel. 01948 666 321. Fax. 01948 66 55 32