For further information please contact SLE Cladding Ltd. Tel. 01948 666 321. Fax.  01948 66 55 32

 

FRP GLASBORD

 

Food Safe Hygienic Wall Cladding Boards

 

Glasbord showing water repellent properties

 
 

Fibreglass panel with Surfaseal

Product.
 FX Glasbord with Surfaseal is a durable semi-rigid building material made from fibreglass reinforced plastic (frp)
 
Surfaseal Finish
Surfaseal is a unique patented surface treatment that, when compared to ordinary frp, exhibits up to ten times the cleanability , six times the stain resistance,  and twice the abrasion resistance.
 
Purpose
FX Glasbord panels are designed for interior wall finishes where durable, hygienic, easy to clean surface is required.
 
Certification and Identification
1/.  The panel has a Class "1" flame spread (per BS476 Part 7) and Class O fire propagation (per BS476 Part 6
 
2/.  Fibreglass Reinforced Plastic does not support mould or mildew (per ASTM D3273 and ASTM D3274)
 
3/. FX Glasbord is designated by 2 red and 1 blue thread on the back of the panels and two fluorescent threads on the front of the panels (visible only under UV light)
 
Operational Temperatures Range
Panels will perform in temperatures from -40 deg. C (-40  deg F) to 54 deg. C (130 deg. F)
 
Design Data
Nominal Thickness Colour Options Size Finish
2.3mm White
Cream
Beige
Grey
Ivory
Silver
1220mm x 2440mm, 3050mm Embossed
Note. White is the popular colour. For availability of other colours please ask SLE staff to investigate.
 
Physical Properties
Property Typical Values Test Method
Flexural Strength 13.6 x103 psi (94 Mpa) ASTM D790
Flexural Modulus 0.608 x 106 psi (4192 Mpa) ASTM D790
Tensile Strength 7.1 x 103 psi (49Mpa) ASTM D638
Tensile Modulus 0.803 x 106 psi (5537 MPA) ASTM D638
Barcol Hardness 45 ASTM D2583
Izod Impact Strength 14ft-lbs (5.1 J/mm) ASTM D256
Gardner Impact Strength 45 in-lbs (5.1 J/mm) ASTM d3029
Coefficient of Linear Thermal Expansion 1.7 x 10-5 in/ini deg F (31um/mi deg C) ASTMD696
R Value 0.32deg/24 hrs @ 25deg.C (77degF) ASTM D570
Surface Burning Characteristics 0.23 hrift2i deg F/Btu (0.047 hrift2i deg C/kcal) ASTMC1114
Taber Abrasion Resistance Class "1" BS476 Part 7
  0.020 deg max wt loss Taber Test
     

For further information please contact SLE Cladding Ltd. Tel. 01948 666 321. Fax.  01948 66 55 32

 

Copyright (c)1999 SLE Cladding Limited.