For further information please contact SLE Cladding Ltd. Tel.
01948 666 321. Fax. 01948 66 55 32
|
TATA
|
|
(formerly Corus and
before that British Steel) |
| |
|
ROOF DECKING PROFILE. |
| |
|
D60 Web Perforated COLORCOAT STEEL
220 N/mm2 |
| |
|
 |
|
Now
with fully supported side lap (not shown above) |
|
Please note that TATA have
withdrawn the R60 roof profile and the C60 wall profile.
|
Ultimate
Section Properties
|
Nominal
Thickness. mm. |
Design Thickness. mm |
Weight
kg/m2 |
Moment
Capacity kNm/m |
Moment of
Inertia cm4/m |
Moment
Capacity kNm/m |
Moment of
Inertia cm4/m |
Web
Crushing kN/m |
Shear
Capacity kN/m |
|
0.70 |
0.66 |
7.01 |
3.22 |
51.10 |
3.12 |
51.10 |
11.07 |
18.91 |
newton.
Unit of force. (symbol: N). One newton is the force
which would give a mass of kilogram an acceleration of
one metre per second per second in the direction of the
force. |
|
Safe Imposed (Positive)
Loads (kN/m2)
SPAN (metres) |
|
Span Conditions |
Thick mm. |
1.80 |
1.90 |
2.00 |
2.10 |
2.20 |
2.30 |
2.40 |
2.50 |
2.60 |
2.70 |
2.80 |
2.90 |
3.00 |
3.10 |
3.20 |
|
Single |
0.70 |
4.10 |
3.89 |
3.69 |
3.52 |
3.36 |
3.02 |
2.65 |
2.33 |
2.06 |
1.83 |
1.64 |
1.47 |
1.32 |
- |
- |
|
Double |
0.70 |
2.55 |
2.36 |
2.19 |
2.05 |
1.91 |
1.97 |
1.69 |
1.59 |
1.50 |
1.42 |
1.34 |
1.27 |
1.21 |
- |
- |
|
Multi |
0.70 |
3.00 |
2.78 |
2.59 |
2.42 |
2.26 |
2.12 |
2.00 |
1.88 |
1.78 |
1.68 |
1.60 |
1.51 |
1.44 |
1.37 |
1.31 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Safe Wind Suction (negative) Loads (kN/m2) |
SPAN (metres) |
|
|
|
|
|
|
|
Span Conditions |
Thick mm. |
1.80 |
1.90 |
2.00 |
2.10 |
2.20 |
2.30 |
2.40 |
2.50 |
2.60 |
2.70 |
2.80 |
2.90 |
3.00 |
3.10 |
3.20 |
|
Single |
0.70 |
5.13 |
4.61 |
4.16 |
3.77 |
3.44 |
3.14 |
2.89 |
2.66 |
2.46 |
2.28 |
2.12 |
1.98 |
1.85 |
- |
- |
|
Double |
0.70 |
5.30 |
4.76 |
4.29 |
3.90 |
3.55 |
3.25 |
2.98 |
2.75 |
2.54 |
2.36 |
2.19 |
2.04 |
1.91 |
- |
- |
|
Multi |
0.70 |
6.63 |
5.95 |
5.37 |
4.87 |
4.44 |
4.06 |
3.73 |
3.44 |
3.18 |
2.95 |
2.74 |
2.55 |
2.39 |
2.23 |
2.10 |
These load span tables have been calculated
in accordance with BS5950 Part 6, and provide safe working
loads (factor 1.5). All profiles comply to MCRMA
manufacturing tolerances. Information contained within this
document is subject to change as Corus is constantly
developing it's products.
For further information please contact SLE Cladding Ltd. Tel.
01948 666 321. Fax. 01948 66 55 32
Copyright (c)1999 SLE Cladding Limited.
|
|
|