D35 GALVANISED STEEL

280 N/mm2

 

   Ultimate Section Properties

Nominal Thickness. mm.

Design Thickness. mm

Weight kg/m2 Moment Capacity kNm/m Moment of Inertia cm4/m Moment Capacity kNm/m Moment of Inertia cm4/m Web Crushing kN/m Shear Capacity kN/m
0.70 0.66 7.50 1.91 13.53 1.95 16.60 24.53 50.77
0.90 0.86 9.65 2.80 18.86 2.78 22.02 39.51 65.77
1.20 1.16 12.86 4.21 27.33 3.88 29.40 67.55 87.93

 

 

   newton.  Unit of force. (symbol: N). One newton is the force which would give a mass of kilogram an acceleration of
   one metre per second per second in the direction of the force.

   Safe Imposed (Positive) Loads (kN/m2)                                 SPAN (metres)

Span Conditions Thick   mm. 1.60 1.70 1.80 1.90 2.00 2.10 2.20 2.30 2.40 2.50 2.60 2.70 2.80 2.90 3.00
0.70 2.29 1.90 1.59 1.35 - - - - - - - - - - -
Single 0.90 3.19 2.64 2.22 1.88 1.60 1.38 1.20 - - - - - - - -
1.20 4.62 3.83 3.21 2.72 2.32 2.00 1.73 1.51 1.33 - - - - - -
0.70 3.44 3.10 2.82 2.57 2.35 2.16 1.99 1.84 1.69 1.49 1.32 - - - -
Double 0.90 5.09 4.59 4.16 3.79 3.47 3.18 2.93 2.60 2.29 2.02 1.80 1.60 1.44 1.29 -
1.20 7.54 6.78 6.13 5.57 5.08 4.66 4.13 3.61 3.17 2.81 2.49 2.23 1.99 1.79 1.62
0.70 4.15 3.76 3.41 3.12 2.86 2.52 2.19 1.92 1.69 1.49 1.32 - - - -
Multi 0.90 6.18 5.58 5.06 4.61 3.97 3.42 2.98 2.60 2.29 2.02 1.80 1.60 1.44 1.29 -
1.20 9.18 8.26 7.48 6.43 5.51 4.75 4.13 3.61 3.17 2.81 2.49 2.23 1.99 1.79 1.62

   Safe Wind Suction (negative) Loads (kN/m2)

SPAN (metres)

Span Conditions Thick   mm. 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70
0.70 4.06 3.55 2.99 2.54
Single 0.90 5.64 4.70 3.96 3.37 2.89 2.50 2.17
1.20 7.53 6.28 5.29 4.50 3.86 3.33 2.90 2.54 2.23
0.70 3.98 3.52 3.14 2.82 2.55 2.31 2.10 1.93 1.77 1.63 1.51
Double 0.90 5.83 5.17 4.61 4.14 3.73 3.39 3.09 2.82 2.59 2.39 2.21 2.05 1.90 1.78
1.20 8.77 7.77 6.93 6.22 5.61 5.09 4.64 4.24 3.90 3.59 3.32 3.08 2.86 2.67 2.49
0.70 4.97 4.41 3.93 3.53 3.18 2.89 2.63 2.41 2.21 2.04 1.88
Multi 0.90 7.29 6.46 5.76 5.17 4.67 4.23 3.86 3.53 3.24 2.99 2.76 2.56 2.36 2.12
1.20 10.96 9.71 8.66 7.77 7.02 6.36 5.80 5.31 4.87 4.49 4.08 3.65 3.27 2.94 2.66

  

   These load span tables have been calculated in accordance with BS5950 Part 6, and provide safe working loads     (factor 1.5). All profiles comply to MCRMA manufacturing tolerances. Information contained within this document is    subject to change as Corus is constantly developing it's products.

 

 

 

 