Maximum Span under Line
Load*
|
Thickness mm |
0.75 |
0.88 |
1.25 |
|
Line load kN/m |
1.5 |
2.0 |
3.0 |
1.5 |
2.0 |
3.0 |
1.5 |
2.0 |
3.0 |
|
Single span (m) |
24.23 |
18.18 |
12.12 |
30.27 |
22.70 |
15.13 |
45.18 |
33.89 |
22.59 |
|
Double / multi span (m) |
29.08 |
21.81 |
14.54 |
36.32 |
27.24 |
18.16 |
54.22 |
40.67 |
27.11 |
* Line loads as defined in BS
5950 Part 6 Section 2.2. Roof loading should be calculated
in accordance with BS 6399 : Part 3 Part 2 for wind
loading) CP & P recommend using a line load of 3kN/m
and a minimum imposed UDL of 1.5kN/m2. Snow and wind
loading may be more severe than this, however.
These load span tables have been calculated
in accordance with BS5950 Part 6, and provide safe working
loads (factor 1.5). All profiles comply to MCRMA
manufacturing tolerances. Information contained within this
document is subject to change as Corus is constantly
developing it's products.
For further information please contact SLE Cladding Ltd. Tel.
01948 666 321. Fax. 01948 66 55 32
Copyright (c)1999 SLE Cladding Limited.
|